11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
76
PLATFORM WILL NOT LOWER
NOTE: For dual pump system, check secondary pump and motor fi rst.
NOTE: Numbers for the electrical
terminals shown in the illus
tration are not stamped on
valve coil. Numbers shown
are for reference only.
1. Try lowering platform (activate
DOWN toggle switch). Only the
motor solenoid and “B” valve
(both located in the pump box)
(FIGS. 76-1 and 76-2) and
“D” valve (on top of LH and RH
columns) (FIG. 76-3) should be
energized while lowering platform.
Connect voltmeter to terminal-1 and
terminal-2 on each valve shown in
FIGS. 76-1 and 76-2. Correct
indication for “B” and “D” valves is
+11 to +12.6 volts dc. If indications
are incorrect, check control
switch and wiring to that valve
(refer to ELECTRICAL SYSTEM
DIAGRAMS section). Replace faulty
wiring or control switch as required.
“D” VALVE
FIG. 76-3
“D” VALVE
“B” VALVE
(LOWERING)
TYPICAL SOLENOID VALVES
(PUMP IS SHOWN FROM GRAVITY DOWN
UNIT WITH HOSES)
FIG. 76-1
TYPICAL
TERMINAL-1
TYPICAL
TERMINAL-2
TYPICAL SOLENOID VALVES
(PUMP IS SHOWN FROM GRAVITY DOWN
UNIT WITH STEEL LINES)
FIG. 76-2
“B” VALVE
(UNFOLDING)
TYPICAL
TERMINAL-1
TYPICAL
TERMINAL-2
TROUBLESHOOTING - GRAVITY DOWN