Avoid making sharp bends in wiring.
CAUTION
REMOVING SWITCH FROM RH RUNNER
FIG. 33-1
SWITCH &
BRACKET
18. If RH runner is being
replaced, unbolt switch
mounting bracket as shown
in FIG. 33-1. Pull switch,
bracket, and cable from the
runner.
BOLTS
LOCK
WASHERS
OPENING FOR
SWITCH
19. If RH runner is being replaced, reinstall
switch, bracket, and cable in runner as
follows. Make a wire sh by feeding 8 feet
of small gauge wire through switch opening
in runner (FIG. 33-1). Pull wire through
channel at lower end of runner. Leave
enough wire at the switch opening to attach
to switch cable, and enough wire to pull at
the lower end of runner. Tie upper end of wire
sh to switch cable connector. Pull connector
and cable through runner until connector
exits lower end of runner. Then, bolt switch
mounting bracket to runner (FIG. 33-1).