PLATFORM WILL NOT RAISE, MOTOR RUNS
TROUBLESHOOTING - GRAVITY DOWN
3. Check the high pressure relief
valve (FIGS. 74-1 and 74-2) for
contamination or defective operation.
Lower the platform to the ground.
Remove the relief valve. Clean or
replace valve as required.
4. Adjust relief valve operating pressure
according to PUMP RELIEF VALVE
PRESSURE SETTING procedure.
1. Check the hydraulic fl uid level in the reservoir.
2. Check for bent parts on the Liftgate that could interfere with normal operation. Look at
columns, runners, and tandem rollers.
WARNING
!
Make sure Liftgate platform is open
and resting on the ground before per-
forming the following step.
NOTE: For dual pump system, check sec-
ondary pump and motor fi rst.
GRAVITY DOWN LIFTGATES: Lower the platform to the ground. Clean dirt and fl uid
from top of reservoir in pump box. Fill the reservoir to correct level indicated on sight
glass (pump box).
POWER DOWN LIFTGATES: Raise the platform to bed height. Fill the reservoir to
correct level indicated on sight glass (pump box).
ACCESS TO PRESSURE
RELIEF VALVE
COVER
COVER
ACCESS TO PRESSURE
RELIEF VALVE
CHECKING PRESSURE RELIEF VALVE
(GRAVITY DOWN PUMP IS SHOWN
FROM UNIT WITH HOSES)
FIG. 74-1
CHECKING PRESSURE RELIEF VALVE
(GRAVITY DOWN PUMP IS SHOWN
FROM UNIT WITH STEEL LINES)
FIG. 74-2